Section 9.1. General

9.1.1.1. Scope

The scope of this Part shall be as described in Subsection 1.1.2. of Division A. 9.1.1.2.

9.1.1.2. Signs

Signs shall conform to the requirements in Section 3.15.

9.1.1.3. Self-Service Storage Buildings

Self-service storage buildings shall conform to the requirements in Section 3.10.

9.1.1.4. Tents and Air-Supported Structures

Tents shall conform to the requirements in Subsection 3.14.1.
Air-supported structures shall conform to the requirements in Subsection 3.14.2.

9.1.1.5. Proximity to Existing Above Ground Electrical Conductors

Where a building is constructed in close proximity to existing above ground electrical conductors the requirements of Subsection 3.1.19. shall apply.

9.1.1.6. Food Premises

The requirements of Subsection 3.7.6. apply to all food premises.

9.1.1.7. Radon

In addition to all other requirements, a building in the following designated areas shall be designed and constructed so that the annual average concentration of radon 222 does not exceed 250 millibecquerels per litre of air and the annual average concentration of the short lived daughters of radon 222 does not exceed 0.02 working levels inside the building for,

(a) the Town of Elliot Lake in the Territorial District of Algoma,
(b) the Township of Faraday in the County of Hastings, and
(c) the geographic Township of Hyman in the Territorial District of Sudbury.

9.1.1.8. Building in Flood Plains

(1) Buildings constructed on flood plains shall,

(a) be designed and constructed in accordance with good engineering practice to withstand anticipated vertical and horizontal hydrostatic pressures acting on the structure, and
(b) incorporate floodproofing measures that will preserve the integrity of exits and means of egress during times of flooding.

9.1.1.9. Site Assembled and Factory-Built Buildings (See Appendix A.)

(1) Except as provided in Sentence
(2), a manufactured building intended for residential occupancy is deemed to comply with this Code if it is designed and constructed in compliance with,

(a) CAN/CSA-Z240.2.1, "Structural Requirements for Mobile Homes", and CAN/CSA-Z240.3.1, "Plumbing Requirements for Mobile Homes", if the building is constructed in Sections not wider than 4.88 m (16 ft), or (b) CSA A277, "Procedures for Factory Certification of Buildings".

2) The requirements of this Code shall apply to,

(a) building components designed and constructed outside the place of manufacture, and
(b) site installation of such buildings.

9.1.1.10. Public Pools and Public Spas

(1) Public pools shall conform to the requirements of Section 3.11. and public spas shall conform to the requirements of Section 3.12.

9.1.1.11. Shelf and Rack Storage Systems

(1) Shelf and rack storage systems shall conform to the requirements of Section 3.16.